Wednesday, April 14, 2010

Problem p5000etch SNF 2010-04-14 11:53:32: pressure fluctuation

ran 6 dummies successfully
attempted to run 8 production wafers
wafer 3 failed due to helium leak error
wafer 4 failed due to large pressure fluctuations:
setpoint 250mTorr
fluctuating between 200 and 300mTorr
All gas flows were stable to within 2sccm of setpoint
helium leak rate for wafer 4 was <2sccm

No comments: